Operating Instructions FLYTEC 3030
Seite 1 von 4
1.
On - Off switch
2.
Analog vario display
3.
Digital vario display
Altitude 1: Absolute altitude
Altitude 2: Relative altitude / Stopwatch
5.
Speed display / Time
Peak value memory
6.
Vane wheel sensor plug /
Rechargable battery charging socket
7.
UP key / START / STOP / RESET
8.
DOWN key / Zeroing Altitude 2
9.
Descent tone / descent alarm key
10.
Sound volume key / Vario attenuation
11.
Changeover key - SPEED-TIME-MEMO
12.
Changeover key - Altitude 1 -Altitude 2 -
Chrono
13.
REC switch
14.
Printer connection
Starting:
On 1 or On 2 (1). Two independent batteries (rechargeable). The switch should be set to OFF when the unit has switched off automatically.
Battery control:
Power voltage is indicated on the analog vario display (2) for appro ximately 10 seconds and «Po» for power on the digital vario
display. When all the segments in the ascent sector (green) light up, this indicates that the battery which has been switched on has an energy reserve
of 100%. Inadequate power reserve is indicated continuously when switched on and during operation by the lighting up of one or several segments in
the descent sector (red) and «Po». lf this occurs, the unit does not shift into operating mode.
Please refer to «CHANGEOVER TO RECHARGEABLE BATTERY OPERATION» for BATTERY changing information.
Automatic Power Down:
Power is automatically cut off approx. 30 mins after the unit is last used. The on/off switch must rst be set at OFF before
the unit can be used again.
Setting mode:
1. Change to setting mode by pressing the desired key (9, 10, 11 er 12) for approx. 4 seconds. The corresponding display will then
ash intermittently and can be adjusted.
2. Use the «Up» (7) or «Down» (8) key to set the required value. When entering altitude gures, the number display can be speeded up by continuous
pressing.
3. Finish by pressing the corresponding original key.
Altimeter:
Altitude 1: Absolute altitude. Can be set within weather-dependent tolerances.
Altitude 2: Relative altitude. Can be set whenever required over the whole measure ment range and zeroed at any time by pressing the key «CLEAR
ALTI 2» (8). It can also be zeroed while ALTI 1 is shown on the display.
Opening the changeover key ALTI 1-ALTI 2 (12) indicates the desired altitude and marks it with an arrow.
Pressing the changeover key (12) for approx. 4 seconds will cause the unit to change to the adiustment mode of the altitude currently displayed (see
Setting mode).
N.B. While a  ight is being recorded (REC switch set to ON), the adjustment mode for Altitude 1 is not available. The altitude can only be reset after
recording has been switched off.
Altitude gain/loss:
Altimeter 2 (ALTI 2) can he used to show a gain or loss in altitude as it can be zeroed at any time using the key «CLEAR ALTI 2»
(8), even while ALTI 1 is displayed.
Vario analog:
Fully automatic segment display over the entire range. Individual segments remain displayed until the end of the rst scale sector is
reached. They are then deleted from zero in the secondscale sectorpass again until the end of the second scale sector is reached.
Vario digital:
Display over the entire range.
Digital vario attenuation:
Changeover into the vario attenuation setting mode is effected by pressing the volume key (10) for approx. 4 seconds (c.f.
Setting mode).The following average value computations can be selected for the digital vario display:
0 = average value for the last second (5 measurements per second)
5 = average value for the last 5 seconds
10 = average value for the last 10 seconds
15 = average value for the last
15 seconds
Przeglądanie stron 0
1 2 3 4

Podsumowanie treści

Strona 1

Operating Instructions FLYTEC 3030Seite 1 von 41. On - Off switch2. Analog vario display3. Digital vario display4. Altitude 1: Absolute altitude Altit

Strona 2

Seite 2 von 420 = average value for the last 20 seconds 25 = average value for the last 25 seconds 30 = average value for the last 30 seconds The anal

Strona 3

Attachment: Clip or special attachment ( t to the rear of the unit). The clip can be unscrewed, twisted 90º and re tted.Servicing, repairs: Return t

Strona 4

Seite 4 von4FLYTEC 3030 Barogroph: Procedure for of cial FAI observers1.The observer must familiarize himself with the instrument for a period of a l